Korean J Med > Volume 74(4); 2008 > Article
The Korean Journal of Medicine 2008;74(4):368-375.
Effects of long-term triple anti-platelet therapy with low-dose cilostazol after drug-eluting stent implantation
Dong Han Kim, Joon Young Kim, Seung Won Moon, Jong Hyuk Jung, Hyuk Seung Yang, Jang Hyun Cho, Myung Ho Jeong
경희대학교 의과대학 순환기내과학교실
원저 : 약물방출 스텐트 시술 후 항 혈소판 삼제 복합치료의 효과
김동한, 김준영, 문승원, 정종혁, 양혁승, 조장현, 정명호
Abstract
Background/Aims : A recent clinical trial demonstrated that triple anti‐platelet therapy resulted in significantly larger minimal luminal diameter and lower restenosis rate compared with conventional therapy after bare‐metal stent (BMS) implantation. However, it is uncertain that this result will be repeated after drug‐eluting stent (DES) implantation, especially with low‐dose cilostazol therapy. Thus, we performed a prospective, randomized study to evaluate the effectiveness of long‐term triple therapy with low‐dose cilostazol after DES implantation. Methods : We analyzed 109 patients (132 lesion) prospectively, who underwent successful coronary DES implantation. The patients were divided into two groups according to combined anti‐platelet regimen: triple combination of aspirin, clopidogrel, and low‐dose cilostazol (50 mg/bid) (Group I, n=56) or dual combination of aspirin and clopidogrel (Group II, n=53) for 6 months. The minimal luminal diameter and binary restenosis rate were compared at 6‐month follow‐up by coronary angiogram. The rates of stent thrombosis, major adverse cardiac events (MACE), and bleeding complication were also analyzed. Results : The baseline clinical and angiographic characteristics were not different between the two groups. Angiographic follow‐up was performed in 80 patients (109 lesions, 74%). The minimal luminal diameter at 6 month was 2.25¡¾0.63 mm in group I and 2.30¡¾0.56 mm in group II (p=0.742). Restenosis occurred in 4 patients (7.2%) in group I and 3 patients (5.6%) in group II (p=0.611). There were no differences in the rates of stent thrombosis, MACE, or bleeding complications between the two groups. Conclusions : Long‐term triple anti‐platelet therapy with low‐dose cilostazol after DES implantation was not effective in obtaining larger minimal luminal diameter or reducing restenosis rate, but it was used safely without increasing bleeding complication.
Key Words: Platelets; Cilostazol; Stents; Restenosis


TOOLS
METRICS Graph View
  • 1,283 View
  • 14 Download

Editorial Office
101-2501, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-2271-6791    Fax: +82-2-790-0993    E-mail: kaim@kams.or.kr                

Copyright © 2024 by The Korean Association of Internal Medicine.

Developed in M2PI

Close layer
prev next